Tracking fits

A tracking fit recovers knob strengths by tracking measured initial conditions through the MAD-NG model and comparing the result with the measured turn-by-turn data. A fit is defined by an accelerator, four configuration objects and an optional FitterOptions. fitter.run() returns a FitResult: the fitted knobs, their 1-sigma uncertainties under the same knob names, and diagnostics (why and after how many epochs the fit stopped).

Object

Role

Accelerator subclass

Machine definition: sequence file, kinetic energy, BPM pattern and the knob families to fit (errors, misalignments).

solver

OptimiserConfig (adam or lbfgs: epoch count, learning-rate schedule, stopping rule) or a Levenberg-Marquardt config from tracking_lm_config().

WorkerRuntime

Worker count, worker log level and BLAS threads.

TrackingDataConfig

Batch count, data and validation fractions, momenta in the loss, track length.

SequenceConfig

Magnet range exposed to MAD-NG and BPMs to exclude.

MeasurementConfig

Measurement files, each with a MeasurementDetails (MAD interface options, momentum offset, first BPM).

FitterOptions (optional)

Starting knobs, true strengths, output and checkpoint settings, callbacks, and the TrackingParameters (BPM gains, starts, prior widths).

Fitters

Fitter

Initial conditions

Tracking

ArcByArcFitter

BPM at the start of each range

Forward and backward over the bpm_start_points x bpm_end_points ranges. Set acd_excited=True for AC-dipole data.

ACDMarkerFitter

AC-dipole before/after markers

Bidirectional; the whole ring is observed.

KickerFitter

Kicker marker

One worker, forward only, turns_per_track turns.

ACDSinusoidFitter

Before-marker, every turns_per_track turns

Back-to-back turns_per_track-turn tracks through the model AC kickers.

All fit families, the knob families of each machine and the solvers are listed in Fit Families.

KickerFitter also takes the kicker_name and turns_per_track. The measurement data must contain x, px, y and py at the kicker marker, and the sequence must contain the kicker element.

Example

from pathlib import Path

from accelmo.config import OptimiserConfig, TrackingDataConfig, WorkerRuntime
from accelmo.fitting.config import OutputConfig, SequenceConfig
from accelmo.machine.accelerators import LHC
from accelmo.tracking import (
    ArcByArcFitter,
    FitterOptions,
    MeasurementConfig,
    MeasurementDetails,
)

accelerator = LHC(beam=1, sequence_file="lhcb1.seq", errors={"quad": {"k1"}})

fitter = ArcByArcFitter(
    accelerator=accelerator,
    solver=OptimiserConfig(
        max_epochs=200,
        warmup_epochs=10,
        warmup_lr_start=1e-6,
        max_lr=1e-4,
        min_lr=1e-6,
    ),
    runtime=WorkerRuntime(num_workers=8),
    tracking_data=TrackingDataConfig(num_batches=4),
    sequence_config=SequenceConfig(magnet_range="$start/$end"),
    measurement_config=MeasurementConfig(
        {Path("measurement.parquet"): MeasurementDetails()}
    ),
    bpm_start_points=["BPM.12R1.B1"],
    bpm_end_points=["BPM.20R1.B1"],
    options=FitterOptions(output_config=OutputConfig(write_run_log=False)),
)
result = fitter.run()
print(result.knobs, result.uncertainties, result.diagnostics.reason)

FitterOptions

initial_knob_strengths

Starting values, in optimisation space. Knobs left out keep the model value.

true_strengths

Reference values (file or dictionary) used to report the error of the fit.

debug

Run MAD-NG in debug mode.

output_config

OutputConfig: run log, TensorBoard logging, uncertainty estimation and log files.

checkpoint_config

CheckpointConfig: periodic checkpoints and restart.

initial_conditions_callback

Epoch-end hook that returns refreshed start coordinates for every worker, or None to keep them.

loss_callback

Called each epoch with the loss values.

Validation

TrackingDataConfig.validation_fraction (default 0.1) holds out a disjoint set of turns per file. These are never used for training, so the validation loss is out-of-sample. data_fraction is applied to the remaining training turns.

Closed-twiss fits

The closed-twiss and closed-orbit fitters live in accelmo.poco and return the same FitResult as the tracking fitters.

ClosedOrbitFitter with series=closed_twiss_series(measurements, observables) (closed_twiss_series()) fits knobs so that the periodic model optics match a measured closed twiss. Closed orbit, beta, phase and dispersion are all obtained from one parametric MAD-NG twiss, so they are fitted simultaneously and no starting point is taken from the measurement. The solver is Levenberg-Marquardt, configured by LevenbergMarquardtConfig.

measurements maps each measurement’s pt to a measured optics dataframe; each is one absolute series. Parameters are weighted by the inverse measurement variance; use_errors=False normalises every observable family identically instead. knob_sigmas adds a Gaussian prior of absolute widths.

Closed-orbit fits

ClosedOrbitFitter fits knobs to one or more ClosedOrbitSeries.

machine_state

MAD-X globals (quadrupole strengths, corrector kicks, tune knobs) at which a series was measured. They are fixed inputs and may differ between series. Varying the quadrupole strengths between series makes quadrupole misalignments observable. Accepted forms are a dictionary, a knobs file or a TFS corrector table; accelmo.machine.machine_state.merge_machine_states() combines several. Setting machine_state on the fitter provides a default inherited by every series.

absolute_planes

Planes fitted as absolute orbits. The remaining planes are fitted as the change from the fitter’s own machine_state to the series’ state: the fitter subtracts each measurement’s reference orbit (errors added in quadrature), which is required for those planes. Measured orbits are always passed in absolute.

observables

Fitted quantities: x, y, and the phase advances mu1, mu2 (mu1/mu2 are set per series).

Accepted iterations are stored in fitter.history. Call fitter.close() to shut down the MAD-NG process once the fit is complete.

CalibratedClosedOrbitFitter extends this with BPM gains and corrector kick calibrations as additional parameters, with Gaussian priors sigma_bpm and sigma_corrector. Every k_<corrector> kick a series’ machine_state sets gets a gain; a series may set several or none (an off-momentum orbit). fit_corrector_gains=False fits the BPM gains alone, which is the mode for absolute orbits.

Degeneracy analysis

accelmo.analysis.degeneracy_checker evaluates the eigenspectrum of the Gauss-Newton normal matrix at the initial knobs. Near-zero eigenvalues identify knob combinations that the data cannot constrain, so the problem can be regularised or the knob set reduced before running the fit. Use check_degeneracy() on a tracking fitter.

Terminal dashboard and logs

A tracking fit draws a live terminal dashboard (FitDashboard): a strip of stages (data, model, workers, fit, uncertainty), progress with ETA, the loss history, the best epoch so far and the last warnings. It does nothing when the output is not a terminal; the run log has the numbers then.

Call accelmo.logs.configure_logging() once at the top of a script to print WARNING and above to the terminal and, with file=, write INFO and above to a file. The dashboard hides the console handler while it is on screen and shows warnings in its own strip.

Each worker process writes every record at WorkerRuntime.logging_level (default DEBUG) to workers/python_worker_<id>.log in the run log directory. Only WARNING and above are relayed to the main process, tagged with the worker name, so they reach the dashboard and the main log. A worker with its own python_logfile keeps it.

Note

Workers are forked processes, and the warning relay reaches them only by fork (Linux, the default start method up to Python 3.13). The spawn and forkserver start methods, the default on macOS, Windows and Python 3.14, are not supported: a spawned worker would write its own log file but its warnings would not reach the main process or the dashboard.

Monitoring a fit

Every fit writes a run log under OutputConfig.run_log_root (switch off with OutputConfig(write_run_log=False)). Serve live plots of running and finished fits with:

uv sync --extra monitor
python -m accelmo.monitor RUN_LOG_ROOT --spec my_package.monitor:SPEC

accelmo-monitor is the same command as python -m accelmo.monitor. Then open http://localhost:5006. On a remote machine, forward the port with ssh -L 5006:localhost:5006 host. Without --spec only the generic panels are shown. See accelmo.monitor and accelmo.runlog.

Testing

pytest -m "not slow"     # fast suite
pytest -m slow           # convergence and end-to-end tests
pytest --cov=accelmo

Markers are listed in tests/README.md. Tests marked serial must not run in parallel (do not combine with -n). The tests under tests/training/ double as worked examples.