The model backend does two jobs in every fit: it computes the model prediction at the BPMs, and it returns the derivative of that prediction with respect to every knob. MAD-NG is the production backend. xtrack is a reference implementation of the same interface, limited in scope (see xtrack backend requirements) and slower (examples/benchmark_madng_vs_xsuite_psb.py); it shows what an xsuite-based fit needs. Cheetah (https://github.com/desy-ml/cheetah) is a possible further backend. The backend is chosen with Accelerator(backend="madng" | "xtrack"); the interface is accelmo.backend.protocol.

Backend interface

A backend is the module accelmo.backend.<name>.engines with:

Name

Contract

open_model(accelerator, *, magnet_range, ...)

Parent-side Model: knob_names, all_bpms, bpms_in_range, cycle_to_start, recount_bpms, apply_initial_model_values, knob_values, close. No derivatives.

TrackingEngine(config, plan: TrackRequest, init_knobs, *, worker_id, logfile)

set_knobs, load_particles, set_pts, set_start_coords, preflight, track(batch, *, start_derivatives) -> TrackResult, close

ClosedOrbitEngine(config, init_knobs, *, optics_names, orbit_coords, worker_id, logfile, extra_knobs=None)

knob_names, fit_pt, set_knobs, get_vars, set_vars, set_pt, set_warm_start, solve(observables, *, jacobian=True) -> ClosedSolution | None, close. extra_knobs (zero-valued BPM-gain/corrector-gain knobs, pt not fitted) and scale_globals are MAD-NG only

closed_orbit_table(accelerator, magnet_strengths, pt, machine_state, columns)

Plain closed-orbit table (momentum reference)

Shapes and conventions (docstrings of accelmo.backend.protocol):

  • Knobs are named as in accelmo.machine.knob_names (MQ.1.dk1l); pt is fitted as the last Jacobian column when fit_pt is true.

  • TrackRequest.geometry (a TrackGeometry) is the tracked segment: observed BPM range, sdir, start marker, cycle target and anchors. A ClosedOrbitEngine has none: it observes the whole ring and does not cycle.

  • TrackResult.obs[o] is (P, N), d_dk[o] (P, K, N), d_dc0[o] (P, 4, N).

  • ClosedSolution.values is (n_observables, n_bpms) and jacobian (n_observables, n_bpms, n_knobs), rows in the requested observable order; jacobian=False returns the values only (loss-only evaluation).

  • A lost closed orbit is None; lost particles are counted in TrackResult.n_lost.

  • get_vars / set_vars read and set global variables of the machine state (corrector kicks, tune knobs).

  • set_warm_start(key) starts the next closed-orbit search from the last orbit solved under key; a backend without warm starts makes it a no-op.

What the optimiser needs

Python computes the loss, the gradient, the Gauss-Newton matrices, the weights and the uncertainties. A worker only has to return arrays.

Fit

Input per evaluation

Output

Tracking

Knob values, start coordinates (x, px, y, py) and pt of every particle

x, y, px, py at every observed point: (n_particles, n_points); d{o}_dk for each of them: (n_particles, n_knobs, n_points); with fit_start_coords, d{o}_dc0: (n_particles, 4, n_points); the number of lost particles

Closed orbit and closed twiss

Knob values and the measurement pt

BPM names in model order; values (n_observables, n_bpms); Jacobian (n_observables, n_bpms, n_knobs); None when the closed orbit is lost

Validation (tracking)

Knob values, start coordinates, pt

The observables only

The full Jacobian is needed, not only the gradient of the loss. Levenberg-Marquardt and the sandwich uncertainties (Cov = A⁻¹ B A⁻¹) are built from it. Adam and L-BFGS need only the gradient of the loss.

Everything outside accelmo/backend is backend independent: fitters, workers, the worker pool and message protocol, data loading, optimisers, and the loss, gradient and uncertainty assembly. A new backend implements the interface above; element patterns of the accelerator families (MAD-NG Lua patterns today) are translated inside the backend.

Sources of the gradient

Only automatic differentiation is used. Finite differences are not a gradient source; the tests use them as an independent check of the exact derivatives.

MAD-NG (production)

xtrack (reference)

Cheetah (possible)

Derivative method

Knobs are TPSA parameters; one pass returns the value and every derivative

Knobs are TPSA parameters of xtrack.tpsa.ParticlesTpsa (KnobParameters); one parametric track per particle returns the value and every derivative

PyTorch autograd through the tracking

Model runs per gradient

1 per batch

1 per particle

1 forward and 1 backward pass for the loss gradient

Full Jacobian

Included

Included

One backward pass per output, or one forward-mode pass per knob

Hardware

CPU

CPU only

CPU or GPU (PyTorch)

Closed orbit

cofind and twiss

line.twiss(method="4d") plus the fixed-point shift (below)

Not confirmed here

Evidence in this repository

All fits

accelmo.backend.xtrack, tests/backend/test_xtrack_backend.py

None

xtrack

xtrack is already the reference of this repository: xtrack_tools builds the lines that generate every test measurement. Its exact derivatives come from xtrack.tpsa with the madng_tpsa package, which is the MAD-NG method.

../poco_fodo_study/fodo_study/xs_ring.py implements it for the closed-orbit Jacobian of a FODO ring:

  1. Build the line, one line variable per fitted quadrupole strength, and set line.config.XTRACK_MULTIPOLE_NO_SYNRAD = True (TPSA tracking needs radiation off).

  2. Make the knobs parameters: descriptor = madng_tpsa.Descriptor(6, 1, num_params=K, param_order=1), then KnobParameters(line, knob_names, descriptor).apply().

  3. Find the closed orbit with line.twiss(method="4d", only_orbit=True) and start a ParticlesTpsa on it.

  4. Track one turn with multi_element_monitor_at set to the BPMs and the monomials of interest recorded: R_s (the four transverse first-order terms) and P_s (one term per parameter).

  5. Solve the fixed-point shift S = (I - R)^-1 P and return d(orbit_s)/dk = R_s S + P_s.

The same module offers TpsaOptics (optical functions and their parameter derivatives from a map of order 2 or more) and ActionTpsaTrack (a line.match action that returns an analytic Jacobian).

Properties that bear on a worker:

  • ParticlesTpsa is a single map: scalar coordinates only. A batch of P particles is P parametric tracks, run one after the other on the CPU.

  • Radiation must be off.

  • The reproducer ../poco_fodo_study/scratch/xtrack_tpsa_monitor_overhead.py times the Python overhead of recording many monomials at many monitors.

  • Not checked: which elements of the LHC, PSB and SPS lattices (edges, fringes, multipoles, kickers, ACD) the TPSA kernels support, and the time of one batch.

An xtrack worker:

  1. Builds the line with xtrack_tools.env.initialise_env and sets the knobs as line variables.

  2. Closed-orbit fits: returns the orbit (and, for closed twiss, the optics) at the BPM rows with the TPSA Jacobian.

  3. Tracking fits: builds particles at the measured start coordinates, tracks the batch with one monitor per BPM, and returns the observables with the Jacobian.

  4. Reports a lost particle through the lost-particle count and a lost closed orbit as None.

Cheetah

Cheetah is a PyTorch package for differentiable beam dynamics. Its elements are torch.nn.Module objects, a lattice is a Segment, a beam is a ParticleBeam or a ParameterBeam, and it is vectorised with PyTorch broadcasting. Its documentation describes the gradient of the beam position at the end of a lattice with respect to the element strengths, and states that particle losses in Aperture are not differentiable.

A Cheetah worker would do the following:

  1. Convert the lattice to a Segment and set the knob attributes as tensors with requires_grad=True.

  2. Track a ParticleBeam made of the measured start coordinates, with one observation point per BPM.

  3. For Adam and L-BFGS: build the weighted loss in PyTorch and call backward once. The gradient arrives for all knobs.

  4. For Levenberg-Marquardt and the uncertainties: build the Jacobian with torch.func.jacfwd or jacrev over the knob tensor, and return it in the contract shape.

Because PyTorch differentiates the loss directly, step 3 replaces both the observable arrays and the derivative arrays for the gradient-descent optimisers. The worker reply (GradReply) already carries only the loss and the gradient.

Items to check before choosing Cheetah. None of these is confirmed in this repository or in the sources read for this page:

  • Whether the element models cover what the fits use: thick and thin quadrupoles, dipoles with edges and fringes, sextupoles, kickers, and the misalignment and tilt attributes of each family in Fit Families.

  • The order of the tracking maps (linear or nonlinear) and the resulting difference from MAD-NG method=6. The tests record the xsuite and MAD-NG agreement floor of the loss (test_controller_acd.py: about 5e-15 for the PSB ACD fit); a different model sets a different floor.

  • Off-momentum tracking with pt per particle.

  • A closed-orbit solve and a ring twiss, which the POCO fitters need. Without them a closed orbit has to be found with an outer solver, and its derivative needs the implicit function theorem.

  • A path from the MAD-X sequences used here to a Segment.

Checking a backend

Use the existing tests as the acceptance criteria.

  1. Jacobian. Repeat tests/mad/test_madng_xsuite_misalignment.py with the new worker in place of MAD-NG: the orbit and the Jacobian columns must agree with the xsuite finite difference within the same 1e-3.

  2. Loss at the truth. Run the pattern of tests/training/test_lhc_acd_pipeline.py: the loss at the true strengths must be far below the loss at the nominal ones.

  3. Fit. Run a controller test (tests/training/controller/) with Levenberg-Marquardt and compare relative_truth_errors with the MAD-NG values stored in the test comments.

xtrack backend requirements

accelmo.backend.xtrack fits only knobs whose xsuite field is TPSA-capable. Measured on xtrack 0.118.6 (_float_or_tpsa_fields of each element class):

Element class

TPSA fields

Consequence

Quadrupole

k1, k1s

quad k1 knobs supported (<Q>.dk1l adds dk1l / L to k1)

Bend, RBend

k0, k1, k2

bend k0 knobs supported (<B>.dk0l adds dk0l / L to k0)

Sextupole, Octupole

k2, k2s / k3, k3s

Not wired yet (no family uses the thick field)

Multipole (thin correctors, thin sextupoles)

none

No kick, knl[n] or ksl[n] knobs; corrector kicks are machine state only

Any element: shift_x, shift_y, rot_s_rad

none

No misalignment knobs (dx, dy, ds, tilt)

Cavity, AC kickers

none

No volt knobs, no AC-kicker tracking

Other requirements of the backend:

  • TPSA tracking needs line.config.XTRACK_MULTIPOLE_NO_SYNRAD = True: proton machines only.

  • The TPSA kernels contain no aperture elements; the backend drops every Limit* element (MAD-NG tracks with a 100 m aperture).

  • xsuite keeps no MAD-X kind; the backend reads each element’s base kind from the sequence file declarations (madx_element_kinds).

  • Not supported: backward sequences (LHC beam 2), sdir = -1, fitted pt, PSB cell grouping, LHC bend normalisation, tracking anchors (ACD/kicker markers), b2 errors, calibrated closed orbit, optics observables (closed orbit x, px, y, py only), a named range over more than one turn, and the momentum-reference table. Each raises NotImplementedError.

Agreement with MAD-NG on PSB ring 3 (tests/backend/test_xtrack_backend.py, scratch_tmp/xt/compare_backends.py):

  • Knob names and observed BPMs: identical (48 quad knobs, 16 BPMs).

  • Closed orbit from one corrector state: 5e-12 m vertical, 3e-13 m horizontal on ~1 mm; the corrector sign conventions agree.

  • One-turn horizontal tracking: x 6e-10 m on 5 mm, d(x)/dk 6e-9 on 4e-2.

  • Vertical plane, off momentum: with the bundled MAD-NG release (mad_Linux 1.1.15) d(y)/d(y0) differs by 3e-4 relative at pt = 1e-3 (1e-6 on momentum), accumulated in the quadrupoles. The xsuite TPSA map equals plain xsuite tracking (2e-17 m) and finite differences (6e-10). With the MAD-NG dev build (MAD/src/mad, or MAD/src/mad_fringe) the one-turn y difference drops from 3.2e-7 m to 4.3e-10 m, the same as x: the release binary’s off-momentum quadrupole map differs, not xsuite.

  • Closed orbit with quad knobs at ±2e-3 and correctors on: 1e-4 relative. The knob enters MAD-NG as dknl[2] and xsuite as a thick k1 change, which are different maps.