Fit Families

A fit changes knobs until a model reproduces a measurement. This page lists what can be measured, which fitter reads it, what is fitted and which solver runs.

What every fit does

  1. Load the machine (sequence, beam, energy) and create one knob per fitted magnet attribute.

  2. Split the measurement across worker processes. Each worker owns one MAD-NG instance.

  3. Send the current knobs to every worker. Each worker returns the model prediction at the BPMs and its derivative with respect to every knob.

  4. Sum the weighted squared residuals into a loss and a gradient.

  5. Update the knobs with the optimiser. Repeat from step 3.

  6. Return the best knobs, their 1-sigma uncertainties and why the fit stopped (FitResult).

Two engines

Tracking (accelmo.tracking)

POCO (accelmo.poco)

Measurement

Turn-by-turn BPM data: x, px, y, py per turn

Closed orbit, or closed twiss (orbit, beta, phase, dispersion), at one or more momenta

Model side

MAD-NG track from measured start coordinates, with the knobs as TPSA parameters

MAD-NG closed-orbit solve and parametric twiss with the knobs as TPSA parameters

Solver

Adam, L-BFGS or Levenberg-Marquardt (OptimiserConfig.optimiser_type)

Levenberg-Marquardt

Split of the data

Batches of turns, one particle per turn; held-out validation turns

One worker per series of measurements

Result

FitResult

FitResult

The engines share the worker protocol, the worker pool, the weights, the uncertainty estimate and the run log (accelmo.fitting). They do not import each other.

Tracking fitters

All tracking fitters are subclasses of TrackingFitter. They differ in where the particles start, which direction they are tracked, and which BPM readings are compared.

Fitter

Start coordinates

Tracking

Readings compared

ArcByArcFitter

Measured, at the first BPM of each range

One turn, forward and backward over every bpm_start_points x bpm_end_points range

BPMs inside each range

ArcByArcFitter with acd_excited=True

Same

Same. A range that contains the AC dipole is tracked the other way round the ring

BPMs inside each range

ACDMarkerFitter

Measured, at the AC-dipole <acd>_before and <acd>_after marker rows

One turn, forward from after and backward from before

All BPMs

KickerFitter

Measured, at the kicker marker rows

turns_per_track turns forward, one worker per file

All BPMs

ACDSinusoidFitter

Measured, at the before-marker every turns_per_track turns

Back-to-back turns_per_track-turn tracks through the model AC kickers

All BPMs, every turn

Each fitter builds a tracking plan (tracking/config/tracking.py) that fixes the ranges and the markers. The step-by-step run of one fit is in Tracking Fit Tour.

Measurement files

One parquet file per measurement, with the columns name, turn, bunch_number, x, px, y, py, var_x, var_y, var_px, var_py. MeasurementConfig maps each file to a MeasurementDetails (MAD interface options, momentum offset machine_deltap, first_bpm). Columns, units and the machine state are described in Measurement Data.

  • ACDMarkerFitter and ACDSinusoidFitter need <acd>_before and <acd>_after rows.

  • KickerFitter needs x, px, y, py at the kicker marker.

Tracking fit options

These TrackingParameters fields (FitterOptions.parameters) change what a tracking fit parameterises. All but bpm_gain_sigma need a Levenberg-Marquardt fit (solver=tracking_lm_config(n), tracking_lm_config()). The last two rows are TrackingDataConfig fields.

Field

Effect

fit_start_coords

Every particle’s start x, px, y, py becomes a parameter

bpm_gain_sigma

One gain per BPM and plane, reading = (1 + g) x position, with a Gaussian prior of this width

starts_follow_gains

Starts are functions of the BPM gains; the gradient includes that path (docs/start_gain_chain_rule.md)

bpm_gain_zero_mean_planes

Holds the mean gain of the listed planes at zero

knob_sigmas

Zero-centred Gaussian prior on named knobs

optimise_momenta

Includes px and py in the loss

validation_fraction, data_fraction

Held-out and used fractions of the turns of each file

POCO fitters

All POCO fitters are subclasses of LMFitter and use Levenberg-Marquardt.

Fitter

Measurement

Fitted in addition to the knobs

ClosedOrbitFitter

ClosedOrbitSeries: closed orbits (x, y), each with a pt and a machine_state; a closed-twiss series (closed_twiss_series()) adds beta, alpha, phase and dispersion at one pt, with absolute orbit planes

Nothing; accelerator.optimise_energy fits pt

CalibratedClosedOrbitFitter

Same

BPM gains and corrector kick gains, with Gaussian priors sigma_bpm and sigma_corrector

machine_state is a set of fixed MAD globals (quadrupole strengths, corrector kicks, tune knobs). Planes listed in absolute_planes are fitted as absolute orbits; the other planes are fitted as the change from the fitter’s own machine_state, using each measurement’s reference orbit.

Knob families

Accelerator(errors=..., misalignments=...) chooses what is fitted. Both are dictionaries from a family name to a set of attributes. Each family is a group of magnets selected by a name pattern. Elements whose nonzero attribute is zero get no knob.

Machine

Family

Element pattern

errors

misalignments

LHC

bend

MB%., MB[RXWAL]%w*%.

k0

quad

MQ%.

k1

dy

other_quad

MQ[^.TSY]

k1

dx, dy

sextupole

MSS?%.

k2

corrector

MCB

kick

PSB

quad

^BR%.Q[FD][OE]%d+$

k0s, k1, k1s

ds, dx, dy, tilt

bend

^BR%.BHZ%d+$, ^BR%.BSW%d+L%d+%.%d+$

k0

ds, dx, dy, tilt

sextupole

^BR%d+%.XNO%d+L1$

knl[3]

skew_sextupole

^BR%d+%.XSK[26]L4$

ksl[3]

corrector

^B[RE]%d+%.DHZ%d+L%d+$, ^B[RE]%d+%.DVT%d+L%d+$

kick

acd

^hackicker_[ab]$, ^vackicker_[ab]$

volt

SPS

quad

^Q[FD]A?%.

k1

sextupole

^LS[FD]A?%.

k2

FCC

quad

^Q[DF][123]AM?%.%d+$

k1

corrector

^[HV]COR_

hkick, vkick

Other fitted parameters:

optimise_energy=True

Fits the beam momentum offset pt.

custom_knobs_to_optimise

Extra global MAD variables, by name.

Knob names follow the element name, for example MQ.12R3.B1.dk1l (integrated gradient error) and <element>.tilt. A tilt knob starts at 1e-9 rad. Values the fitter reports are in optimisation space.

Solvers

solver

Behaviour

OptimiserConfig(optimiser_type="adam")

Mini-batch gradient descent: one step per batch, learning rate warmup then decay

OptimiserConfig(optimiser_type="lbfgs")

Quasi-Newton step with a normalised gradient, history lbfgs_history_size, step capped by lbfgs_max_step_norm

LevenbergMarquardtConfig (tracking_lm_config)

Gauss-Newton step with damping, over every batch. Required by the options above that add parameters

stage_epochs runs the fit in stages that restart the learning-rate schedule. The POCO fitters always use Levenberg-Marquardt, configured by LevenbergMarquardtConfig.